|

Build Your Online Product Catalogs?
Product Name: |
potential conveyor rectifier
|
Supply Ability: |
15000sets |
Related proudcts |
rectifier, |
Specifications |
DC-1 potential conveyor |
Price Term: |
FOB,CIF |
Port of loading: |
Fuzhou,Xiamen |
Minimum Order |
1set |
Unit Price: |
|
|
General The potential conveyor could isolate and transform pipe-soil potential of buried metal pipeline to be standard industrial signal(4 ~ 20mA). The potential conveyor has been equipped with RS485 data transmission port, which is convenient for collecting and managing data. The pipe-soil potential can be displayed by LCD. 1 Technical index 1.1 Power: AC single phase AC220V ˇŔ 1 C% ,50Hz ˇŔ 5%; DC+24V(***ermined by users). 1.2 Safety Requirements 1.2.1 Insulation Resistance: Insulation resistance which is relative power input terminals to encloser is more than 2 MQ. 1.2.2 Dielectric strength 1.2.2.1 When using alternating current power, between power input terminals and encloser should be able to endure AC 1500V, 50Hz(virtual value) test pressure for 1 min, and should be no flashover or breakdown. When using direct current power, between power input terminals and encloser should be able to endure DC500V test pressure for 1 min, and should be no flashover or breakdown. 1.2.2.2 Between power input terminals and encloser can able to endure 500V, 50Hz (virtual value) test pressure for 1 min, and there is no flashover or breakdown. 1.2.3 Dielectric isolation: Among potential input terminal, current output terminal and power should be able to endure 750V, 50Hz (virtual value) test pressure for 1 min, and should be no flashover or breakdown. 1.3 Input range of pipe-soil potential: 0 ~ 3000mV. 1.4 Reference input impedance is more than 1 MQ. 1.5 Output current: (4~20)mA standard industrial signal. 1.6 Load resistance range: 0-600 Q. 1.7 Transform precision of potential-current is better than 1%. 1.8 Resist AC interference: On condition that the value of AC interference voltage between ˇ°Referenceˇ± terminal and ˇ°Zeroˇ± terminal is 50Hz, 30V, the precision of potential-current is better than 1%. 1.9 Resist instantaneous interference: The conveyor is normal after inflicting 1 KV instantaneous DC high-pressure for 20 M s on pipe-soil potential input terminal. 1.10 Dimension: 338mm x 193mm x 56mm. 1.11 |
Company: |
Fujian Changlian Electronic Co., Ltd
|
Contact: |
Ms. haley lai |
Address: |
No.17 Jingdong Industry Park Sanyuan District |
Postcode: |
|
Tel: |
86 0598 8808628 |
Fax: |
0598-8806628 |
E-mail: |
|
|
|
|